Gear card 2 engine
2 motors gear card to give start / stop command to two two-phase or three-phase motors max. 6A.
The 2-motor gear card is useful for giving the start / stop command to two two-phase or three-phase motors max. 6A.
It provides the auxiliary safety and morse pressure control command (or other device in series with the motor control remote control coil), common for both motors and two engine run commands, one for each motor. The movement of one engine inhibits the travel of the other.
TECHNICAL FEATURES
Supply |
|||
Supply voltages |
230-260-400-440 |
Vac |
± 10 % single or 3 phases selectable by jumper |
Frequency |
50 – 60 |
Hz |
|
Absorption on the network (excluding the motor) |
10 |
mA |
With 230Vac |
6 |
mA |
With 440Vac |
|
Internal F1 fuse |
2 |
A |
5x20 fast (glass) |
Max. cable section |
The power supply of the board is taken from the contactor |
||
Contactor K1 |
|||
Number of contacts |
3 NA + 1NC |
|
|
Maximum applicable load (motor absorption) Rated operational current in AC-3 up to 6A |
0.75 (1HP) |
KW |
With 230 Vac single phase |
1.5 (2HP) |
KW |
With 230 Vac three phase |
|
2 (3HP) |
KW |
With 380 Vac three phase |
|
2.5 (4HP) |
KW |
With 440 Vac three phase |
|
Mechanical life |
10.000.000 |
operations |
|
Max. cable section |
2.5 |
mm2 |
|
Buttons input: ENGINE START, ENGINE PRESSURE, AUXILIARY INSERTION |
|||
Required contacts |
1 NA |
|
|
Voltage on contacts |
24 |
Vac |
|
Current on contacts |
60 |
mA |
|
Max. cable section |
2.5 |
mm2 |
|
Auxiliary insertion disabling voltage |
184 |
Vac |
With 230 Vac |
208 |
Vac |
With 260 Vac |
|
320 |
Vac |
With 400 Vac |
|
352 |
Vac |
With 440 Vac |
|
Mechanical characteristics |
|||
Fixing holes |
193 x 82 |
mm |
|
Dimensions (Width x Height x Depth) |
201.5 x 91 x 61 |
mm |
|
Weight |
1074 |
g |
|
Environmental characteristics |
|||
Operating temperature |
0 – 50 |
C° |
|
Relative humidity |
35 – 85 |
% |
|
Degree of protection |
IP00 |
|
|