Braking Card 6A
Braking card with 6A contactor.
The braking card with 6A contactor mod.LBZZ15401 is designed to electronically drive and brake single-phase and three-phase asynchronous motors. It shows all its effectiveness when it is necessary, in emergency situations, to stop briefly the rotation of blades, cutters and tools in general whose normal arrest could damage people or things.
The braking is done by the injection of direct current in two phases and can be activated after each ignition or in particularly dangerous conditions such as the opening of a protective casing.
In both cases, the shutdown occurs in the shortest possible time keeping the current injected in the motor under control in order not to overheat the windings too much.
Thanks to its use, you can avoid using self-braking engines with the following advantages:
- - no longer support the maintenance of abrasive discs;
- - braking time not depending on the state of the abrasive discs;
TECHNICAL FEATURES:
Supply |
|||
Supply voltages |
230-260-400-440 |
Vac |
± 10 % single or 3 phases |
Frequency |
50 – 60 |
Hz |
|
Internal fuse |
2 |
A |
|
Max. cable section |
The power supply of the board is taken from the contractor |
||
Contractor K1 |
|||
Number of electrical contacts |
3 NA + 1NC |
|
|
Rated current |
3 |
A |
With 230 V AC3 |
2.2 |
A |
With 400 V AC3 |
|
Mechanical life |
10.000.000 |
operations |
|
Max. cable section |
2.5 |
mm2 |
|
Auxiliary output |
|||
Voltage |
24 |
VAC |
|
Maximum current available |
100 |
mA |
|
Max. cable section |
2.5 |
mm2 |
|
Safety limit switch |
|||
Required contact |
Contact in exchange |
||
Voltage on the contact |
24 |
Vac |
|
Current on the contact |
|
mA |
|
Max. cable section |
2.5 |
mm2 |
|
Button input(s) Start /Stop |
|||
Required contacts |
1 NA and 1 NC |
|
|
Voltage on the contact |
12 |
Vdc |
|
Current on the contact |
0.1 |
mA |
|
Max. cable section |
2.5 |
mm2 |
|
Enable input |
|||
Required contact |
NA |
|
|
Voltage on the contact |
24 |
Vac |
|
Current on the contact |
40 |
mA |
|
Max. cable section |
2.5 |
mm2 |
|
Braking |
|||
Braking voltage |
1-35 |
VDC |
With 230 VCA adjustable |
1-39 |
VDC |
With 260 VCA adjustable |
|
2-60 |
VDC |
With 400 VCA adjustable |
|
2-67 |
VDC |
With 440 VCA adjustable |
|
Braking time |
0-15 |
S |
Adjustable |
Maximum braking current |
10 |
A |
|
Mechanical characteristics |
|||
Fixing holes |
184.3 x 82 |
mm |
|
Dimensions (Width x height x depth ) |
200 x 105 x 70 |
mm |
|
Maximum bearable vibration |
|
Hz / mm |
|
Shock |
|
m/s2 |
|
Weight |
|
g |
|
Environmental characteristics |
|||
Operating temperature |
0 – 50 |
C° |
|
Relative humidity |
35 – 85 |
% |
|
Degree of protection |
IP00 |
|
|