Gear card 1 engine
Electronic card to give the drive command to a two-phase or three-phase motor max. 6A via contactor.
The 1 motor gear card is useful for giving the drive command to a two-phase or three-phase max 6A motor via a contactor.
It provides the auxiliary safety command, clamp pressure (or other device in series with the coil of the motor control contactor) and driving gear.
TECHNICAL FEATURES
Supply |
|||
Supply voltages |
230-260-400-440 |
Vac |
± 10 % single or 3 phases selectable by jumper |
Frequency |
50 – 60 |
Hz |
|
Absorption on the network (excluding the motor) |
10 |
mA |
With 230Vac |
6 |
mA |
With 440Vac |
|
Internal F1 fuse |
2 |
A |
5x20 fast (glass) |
Max. cable section |
The power supply of the board is taken from the contactor |
||
Contactor K1 |
|||
Number of contacts |
3 NA + 1NC |
|
|
Maximum applicable load (motor absorption) Rated operational current in AC-3 up to 6A |
0.75 (1HP) |
KW |
With 230 Vac single phase |
1.5 (2HP) |
KW |
With 230 Vac three phase |
|
2 (3HP) |
KW |
With 380 Vac three phase |
|
2.5 (4HP) |
KW |
With 440 Vac three phase |
|
Mechanical life |
10.000.000 |
operations |
|
Max. cable section |
2.5 |
mm2 |
|
Buttons input: ENGINE START, ENGINE PRESSURE, AUXILIARY INSERTION |
|||
Required contacts |
1 NA |
|
|
Voltage on contacts |
24 |
Vac |
|
Current on contacts |
60 |
mA |
|
Max. cable section |
2.5 |
mm2 |
|
Auxiliary insertion disabling voltage |
184 |
Vac |
With 230 Vac |
208 |
Vac |
With 260 Vac |
|
320 |
Vac |
With 400 Vac |
|
352 |
Vac |
With 440 Vac |
|
Mechanical characteristics |
|||
Fixing holes |
132.3 x 67.3 |
mm |
|
Dimensions (Width x Height x Depth) |
141 x 75.5 x 61 |
mm |
|
Weight |
832 |
g |
|
Environmental characteristics |
|||
Operating temperature |
0 – 50 |
C° |
|
Relative humidity |
35 – 85 |
% |
|
Degree of protection |
IP00 |
|
|